Zoom the image with the mouse

PDQ 6W Wide Escutcheon Trim - For Use With 6300 Exit Devices

No reviews yet Write a Review
SKU:
PDQ-6W
Shipping:
Calculated at Checkout
$249.00

Don't see the quantity, finish, or function you are looking for? We can mix, match and "BUILD" the item option set you are looking for - Just call us at 860-537-1328 and our sales staff will assist !

Selected Choose Lever is
Adding to cart… The item has been added
  • Security Image 1
Description

PDQ Latest Price Book

 

PDQ 6W Wide Escutcheon Trim - For Use With 6300 Exit Devices

A wide escutcheon for the 6300 device. Available in 6 lever styles, and 5 functions - including electric locking. Use with wide stile devices, when a more substantial look is desired, or for retrofit where covering existing holes is important.

Trims are non-handed and use simple door prep based on a 2 hole bolt pattern with 7” centers, or a 4 hole bolt pattern with 7”x1-3/8” centers.

PDQ 6300, PDQ 6400 Exit Trim Product Selection Table

Product ImageProduct NameApplicable Exit Devices
   (Click On Link Below To View Product) 6300 Panic Rim/ 6300 Fire Rated Rim 6300 Panic SVR/ 6300 Fire Rated SVR 6300 Panic CVR/ 6300 Fire Rated CVR 6300 Panic Mortise/ 6300 Fire Rated Mortise 6400 Panic Rim/ 6400 Fire Rated Rim 6400 Panic SVR/ 6400 Fire Rated SVR 6400 Panic CVR/ 6400 Fire Rated CVR
PDQ 6N Narrow Escutcheon Trim 6N Narrow Escutcheon X X X X X X X
PDQ 6W Wide Escutcheon Trim 6W Wide Escutcheon X X X X - - -
PDQ 6T Thumlatch Exit Trim 6T Thumblatch X X - X X X -
PDQ 6P Pull Plate Exit Trim 6P Pull Plate X X X - - - -
PDQ 6G Grip Pull Exit Trim 6G Grip Pull X X X X X X X
PDQ 6S Sectional Trim 6S Sectional (Rose) X X X - - - -
PDQ 6C Cylinder Trim 6C Cylinder X X X X X X X
PDQ 6w99 Electrified Exit Trim 6W99 Electrified X X X X - - -

6300 Exit Device Cross Reference And Product Selection Table

ManufacturerRimRim FireVertical RodVertical Rod FireConcealed Vertical RodConcealed Vertical Rod FireMortiseMortise Fire
PDQ
(Click on Link on right to view Exit Device)
6300R 6300RF 6300V 6300VF 6300C 6300CF 6300M 6300MF
CORBIN ED5200 ED5200A ED5400 ED5400A ED5860 ED5860B ED5600 ED5600A
DORMA 9300 F9300 9400 F9400 9100 F9100 9500 F9500
FALCON 25-R F-25-R 25-V F-25-V 25-C F-25-C 25-M F-25-M
HAGER 4501 RIM 4501 RIM FR 4501 SVR 4501 SVR FR 4500 CVR 4500 CVR FR 4500 MOR 4500 MOR FR
SARGENT 8800 12-8800 8700 12-8700 8600 12-8600 8900 12-8900
VON DUPRIN 98/99 98/99-F 98/9927 98/9927-F 98/9947 98/9947-F 98/9975 98/9975-F
YALE 7100 7100F 7110 7110F 7160 7160F 7130 7130F

6400 Exit Device Cross Reference And Product Selection Table

ManufacturerRimRim FireVertical RodVertical Rod FireConcealed Vertical RodConcealed Vertical Rod Fire

PDQ
(Click on link on the right to view Exit Device)

6400R 6400RF 6400V 6400VF 6400C 6400CF
CORBIN ED4200 ED4200MA ED4400 ED4400MA ED4800 ED4800MA
DORMA 9700 F9700 9800 F9800 9600 F9600
FALCON 24-R F-24-R 24-V F-24-V 24-C F-24-C
HAGER 4601 RIM 4601 RIM FR 4601 SVR 4601 SVR FR 4601 CVR 4601 CVR FR
SARGENT 8500 12-8500 N/A N/A 8400 12-8400
VON DUPRIN 33A/35A 33A/35A-F 3327A/3527A 3327A/3527A-F 3347A/3547A 3347A/3547A-F
YALE 7200 7200F 7210 7210F 7220 7220F

Features

• Works only with 6300 wide device

• Uses standard 1-1/8" mortise cylinder

• Standard, SFIC, and other cylinders available

• 6 Available lever styles

• 08/09 Function conversion kit factory installed

• Finishes: 605, 606, 613, 622, 626, 630

• Escutcheon Size - 3" x 9"

• ADA Compliant

Functions

02 Pull Only - Entrance/Pull only when device is dogged. Fixed lever.

08 Classroom - Key locks or unlocks lever.

09 Storeroom - Entrance by lever when unlocked by key. Key removable only when locked.

14 Passage - Entrance by lever, always unlocked.

99 Electrified - Locked/Unlocked electronically. FS/FSF configurable. Entry by key. Key does not change lock state

Applicable Devices

• 6300R Wide Stile Rim Device

• 6300V Wide Surface Vertical Device

• 6300C Wide Concealed Vertical Device

• 6300M Wide Mortise Device (Except 03 Night Latch function)

6W 99 - Electrified Locking/Unlocking Trim

Operation

Field selectable operation - Fail Safe (Unlocked when power removed) or Fail Secure (Locked when power removed). Key allows entry but does not change state of lock.

Features

• Motorized locking/unlocking

• Field changeable from Fail Secure (Default) to Fail Safe

• AC or DC input voltage.

• Works with rim, surface vertical rod and concealed vertical rod devices.

• Two (2) year warranty

• Designed and assembled in the USA, Lancaster, PA.

Electrical Specifications

• Non-polarized power leads

• Power requirements: 12-24VDC/VAC ± 10%

• Average in-rush current: 12-24VDC/VAC: 1A for 1 second

• Average holding current: 12-24VDC: 5mA after 30 seconds 12-24VAC: 15mA after 30 seconds

• Power must be applied for a minimum of 5 seconds

Additional Information
Option:Choose Function (What is a lock function? Click here to view our blog detailing lock functions):
https://blog.locksandsafes.com/2020/07/28/the-definitive-guide-to-lock-functions/
Option:Choose Handing (What is it? Click link here to see our Door Handing Guide):
https://blog.locksandsafes.com/2020/07/28/door-hardware-handing-guide/
Option:Choose Finish (Click here to see our Detailed Door Hardware Finish Guide):
https://blog.locksandsafes.com/2020/07/28/lock-and-door-hardware-finishes/
Option:Choose Keyway (What is it? Click here to see our Lock Cylinder and Keyway Guide for more information):
https://blog.locksandsafes.com/2021/03/17/lock-cylinder-and-keyway-guide/
Option:Choose Antimicrobial Coating Option (Click link here for our Blog on Antimicrobial Coatings):
https://blog.locksandsafes.com/2020/09/07/antimicrobial-coating-on-locks-and-door-hardware/
Icon Loading

Customer Reviews 0 Reviews Write a Review

This product hasn't received any reviews yet. Be the first to review this product!