Zoom the image with the mouse

Command Access UBPK Package | Universal Bathroom Privacy Kit

No reviews yet Write a Review
SKU:
CA-UBPK
Availability:
7-12 Days
Shipping:
Calculated at Checkout
$1,708.88

Don't see the quantity, finish, or function you are looking for? We can mix, match and "BUILD" the item option set you are looking for - Just call us at 860-537-1328 and our sales staff will assist !

Selected Choose Lock Trim is
Selected Choose Lever Style is
Selected Choose Lock Finish (Click here to see our Detailed Door Hardware Finish Guide) is
Selected Choose Hinge Finish (Click here to see our Detailed Door Hardware Finish Guide) is
Adding to cart… The item has been added
  • Security Image 1
Description

SPECIFICATIONS

LPM183/184 Mortise Lock

• Latch retraction in a mortise lock

• No special lock prep required – fits standard mortise pocket prepped for a Schlage “L” series lock

• Utilizes our patented PM/PWM technology

• Circuitry allow for momentary or continuously on “push/pull” applications

• UL listed

Latchbolt Control

Latchbolt retracted by key outside or by inside lever. Applied power electronically (EU) retracts latchbolt for push/pull operation.

Lever Control

• Outside Lever

  • EL - locked electronically: Applied power prohibits Outside lever from retracting latchbolt.
  • EU - unlocked electronically: Applied power allows Outside lever to retract latchbolt.

• Inside Lever Always free egress.

Latchbolt Solenoid Specifications

• Operating Voltage – 24 VDC (+/- 10%)

• Holding Current Amperage - 260mA@24VDC

• Surge Current Amperage - 1.9A for 350ms@24VDC

• Peak Current - 7 A @ 24VDC

• Solenoid coil resistance – 1.75 Ω

• Wire gauge: Minimum 18 gauge 300’ with 18ga wire

Lever Solenoid Specifications

• Operating Voltage – 24VAC/DC (+/- 10%)

• Amperage - 24v = 350mA

• Solenoid coil resistance – 24v = 69Ω

PS220/220B Power Supply

• Built to run up to 2 locks, exit trim & LP motor / solenoid kits

• Robust solid-state outputs - Protects system relays

• Interruption free battery back-up

• Built to last in the USA

• UL listed

Input Voltage

120 VAC, 60 Hz,

Input Fuse: 2 Amp Fuse @ 250VAC

Output Voltage

2A @ 24VDC

2 Solid State I/O’s - 1 A auto resetting fused outputs

Power tap: .5A @ 24VDC

Over-voltage protection

Output Voltage trim pot

Battery Backup

Regulated, independent battery charging

Automatic uninterrupted backup circuit

Battery cables included

Requires (2) 12VDC 7AH batteries

Batteries not included

Mechanical Details

Enclosure dimensions: PS220 (11” W x 11” H x 4” D). PS220B (13” W x 15.5” H x 5” D).

1/2” & 3/4” knockouts on all sides

Hinge-less removable cover; Cam lock not provided

PS220B accommodates (2) 12VDC 7 aH batteries

Product Weight: PS220 - 10lbs; PS220B - 14 lbs

Shipment Weight: PS220 - 11lbs; PS220B - 15 lbs

Electrical

Temperature range: 0 to 49° C; 32 to 120° F

Maximum humidity: 85%

Fire Alarm

Fire alarm link

ETH6WH Hinge

• Easy installation

• 4’ lead at no additional charge

• Non-conductive wire access cap

• UL-F listed

• 3 Year No Hassle Warranty

Latch Retraction

Wire Quantity - 2

  • Wire Gauge - 18
  • Continuous Amps @24VDC - 5.0
  • Surge/Pair (.5 Sec) Amps @24VDC - 16.0

Wire Quantity - 2-4

  • Wire Gauge - 26
  • Continuous Amps @24VDC - 1.0
  • Surge/Pair (.5 Sec) Amps @24VDC - N/A

LED Buttons 

• High efficiency LED technology

• LEDs: Green = Vacant. Red = Occupied.

• Improves switch visibilty, even in daylight

• Flame and impact resistant polycarbonate construction

• Selectable 12/24V AC/DC

Voltage

12 or 24V AC/DC

Current Draw

CM-54i/CM-55I: 130mA

Lumia

Red: 5760 MCD

Green: 3780 MCD

Contact Type

1 SPDT Form ‘C’

Contact Rating

3 A @ 30 VDC

Dimensions

Surface Mount: 5-1/4” x 5-1/4” x 2-1/8” (133mm x 133mm x 54mm)

Flush Mount: 6-1/2” x 6-1/2” x 2” (165mm x 165mm x 51mm)

DS1X Auxiliary Board 

Supply Voltage

12-24 VAC/VDC ± 10%

Power Consumption

30-130 mA; DRY Output

Temperature Range*

-15-150° F

Dimensions

5 1/5” (W) x 1” (H) x 2 1/5” (D)

Relay Hold Time

Up to 60 seconds per relay

Delay Between Relays

Up to 60 seconds per relay with 1/4, 1/2 and 3/4 second options

Housing Material

ABS Plastic

Input Specifications

Inputs 1, 2, 3, 4 - DRY contact

WET Input 5-24 VAC / VDC ± 10%

Contact Rating

Relay 1 (DRY) - 3 A @ 24 VAC / 30 VDC

Relay 1 (WET) - 1A 

Relay 2 - 3A @ 24 VAC / 30 VDC 

Relay 3 - 1A @ 24 VAC / 30 VDC

*If powered by AC voltage and using WET output to convert to DC voltage and current draw of device is greater than 0.9 A, the upper temperature range is 130° F

Low Energy Operator

• Header Profile: 6 1/2” x 4 1/2”

• Motor: 1/8 HP

• Header Finish: clear or dark bronze extruded aluminum

• Push Reveal: 0” to 14”

• Pull Reveal: 0” to 4”

• Total Weight with 39” Header: 45 lbs

• Handed: Specify left/right, push or pull

Drive Train Gear Box

Cast Aluminum-Closed Gearbox

Single and Dual Digital Control Box

Single HA-8 w/Data, 24 VDC, 3A

Operating Voltage (Standard)

115 VAC

Magnetic Limit Switches

Yes

Gear Grease

High Wear Protection

Motor

1/8th HP

Opening/Closing Force

Adjustable 5 to 30 lbs.

Arm Connection

1” Solid Spline Spindle

Adjustable Stop

Yes

Operator Switch

On-Off-Hold Open

Adjustable Spring Tension

Yes

Mechanical Clutch

Standard

Header Finish (Standard)

Clear, Dark Bronze, Extruded Aluminum

Header Finish (Optional)

Paint, Special Anodized Colors, Clad

Push or Pull Application

Yes

Easy Manual Operation

Yes

XP Spring

Optional

Surface Mounting

Yes

Concealed Mounting

Center Pivot, Hinge, or Offset Pivots

Bottom Loading

Optional

Push Reveal

0” to 14”

Pull Reveal

0” to 14”

Special Push & Pull Reveals

Call Us

Push & Go

Optional

Electric Strike Output Power

24 VDC

Fire Door Compatibility

UL10C Approved

Circuit Protection

3 A Fuse

Total Weight w/ 39” Header

45 lbs.

Meets ANSI 156.19

Yes

-->

Command Access Documentation Banner Command Access UBPK Banner

 

Command Access UBPK | Universal Bathroom Privacy Kit

The new UBPK Package is an ideal solution for single occupancy restrooms requiring ADA accessibility including privacy and/or security. Built around the only latch retraction x lever control mortise lock with an integrated door position in the market.

• Utilizes the Only Latch Pullback x Lever Control in a ML Lock

• Includes Access Controls Needed to Add Privacy Function to Single Occupancy Restroom

• Maintains ADA Accessibility

• Includes Wire Diagram

• 2 Packages:

  • UBPK1 - Kit 1 Includes Everything + Add Your Operator of Choice.
  • UBPK2 - Kit 2 Includes Everything Above + A High Quality Low Energy Operator.

SPECIFICATIONS

LPM183/184 Mortise Lock

• Latch retraction in a mortise lock

• No special lock prep required – fits standard mortise pocket prepped for a Schlage “L” series lock

• Utilizes our patented PM/PWM technology

• Circuitry allow for momentary or continuously on “push/pull” applications

• UL listed

Latchbolt Control

Latchbolt retracted by key outside or by inside lever. Applied power electronically (EU) retracts latchbolt for push/pull operation.

Lever Control

• Outside Lever

  • EL - locked electronically: Applied power prohibits Outside lever from retracting latchbolt.
  • EU - unlocked electronically: Applied power allows Outside lever to retract latchbolt.

• Inside Lever Always free egress.

Latchbolt Solenoid Specifications

• Operating Voltage – 24 VDC (+/- 10%)

• Holding Current Amperage - 260mA@24VDC

• Surge Current Amperage - 1.9A for 350ms@24VDC

• Peak Current - 7 A @ 24VDC

• Solenoid coil resistance – 1.75 Ω

• Wire gauge: Minimum 18 gauge 300’ with 18ga wire

Lever Solenoid Specifications

• Operating Voltage – 24VAC/DC (+/- 10%)

• Amperage - 24v = 350mA

• Solenoid coil resistance – 24v = 69Ω

PS220/220B Power Supply

• Built to run up to 2 locks, exit trim & LP motor / solenoid kits

• Robust solid-state outputs - Protects system relays

• Interruption free battery back-up

• Built to last in the USA

• UL listed

Input Voltage

120 VAC, 60 Hz,

Input Fuse: 2 Amp Fuse @ 250VAC

Output Voltage

2A @ 24VDC

2 Solid State I/O’s - 1 A auto resetting fused outputs

Power tap: .5A @ 24VDC

Over-voltage protection

Output Voltage trim pot

Battery Backup

Regulated, independent battery charging

Automatic uninterrupted backup circuit

Battery cables included

Requires (2) 12VDC 7AH batteries

Batteries not included

Mechanical Details

Enclosure dimensions: PS220 (11” W x 11” H x 4” D). PS220B (13” W x 15.5” H x 5” D).

1/2” & 3/4” knockouts on all sides

Hinge-less removable cover; Cam lock not provided

PS220B accommodates (2) 12VDC 7 aH batteries

Product Weight: PS220 - 10lbs; PS220B - 14 lbs

Shipment Weight: PS220 - 11lbs; PS220B - 15 lbs

Electrical

Temperature range: 0 to 49° C; 32 to 120° F

Maximum humidity: 85%

Fire Alarm

Fire alarm link

ETH6WH Hinge

• Easy installation

• 4’ lead at no additional charge

• Non-conductive wire access cap

• UL-F listed

• 3 Year No Hassle Warranty

Latch Retraction

Wire Quantity - 2

  • Wire Gauge - 18
  • Continuous Amps @24VDC - 5.0
  • Surge/Pair (.5 Sec) Amps @24VDC - 16.0

Wire Quantity - 2-4

  • Wire Gauge - 26
  • Continuous Amps @24VDC - 1.0
  • Surge/Pair (.5 Sec) Amps @24VDC - N/A

LED Buttons 

• High efficiency LED technology

• LEDs: Green = Vacant. Red = Occupied.

• Improves switch visibilty, even in daylight

• Flame and impact resistant polycarbonate construction

• Selectable 12/24V AC/DC

Voltage

12 or 24V AC/DC

Current Draw

CM-54i/CM-55I: 130mA

Lumia

Red: 5760 MCD

Green: 3780 MCD

Contact Type

1 SPDT Form ‘C’

Contact Rating

3 A @ 30 VDC

Dimensions

Surface Mount: 5-1/4” x 5-1/4” x 2-1/8” (133mm x 133mm x 54mm)

Flush Mount: 6-1/2” x 6-1/2” x 2” (165mm x 165mm x 51mm)

DS1X Auxiliary Board 

Supply Voltage

12-24 VAC/VDC ± 10%

Power Consumption

30-130 mA; DRY Output

Temperature Range*

-15-150° F

Dimensions

5 1/5” (W) x 1” (H) x 2 1/5” (D)

Relay Hold Time

Up to 60 seconds per relay

Delay Between Relays

Up to 60 seconds per relay with 1/4, 1/2 and 3/4 second options

Housing Material

ABS Plastic

Input Specifications

Inputs 1, 2, 3, 4 - DRY contact

WET Input 5-24 VAC / VDC ± 10%

Contact Rating

Relay 1 (DRY) - 3 A @ 24 VAC / 30 VDC

Relay 1 (WET) - 1A 

Relay 2 - 3A @ 24 VAC / 30 VDC 

Relay 3 - 1A @ 24 VAC / 30 VDC

*If powered by AC voltage and using WET output to convert to DC voltage and current draw of device is greater than 0.9 A, the upper temperature range is 130° F

Low Energy Operator

• Header Profile: 6 1/2” x 4 1/2”

• Motor: 1/8 HP

• Header Finish: clear or dark bronze extruded aluminum

• Push Reveal: 0” to 14”

• Pull Reveal: 0” to 4”

• Total Weight with 39” Header: 45 lbs

• Handed: Specify left/right, push or pull

Drive Train Gear Box

Cast Aluminum-Closed Gearbox

Single and Dual Digital Control Box

Single HA-8 w/Data, 24 VDC, 3A

Operating Voltage (Standard)

115 VAC

Magnetic Limit Switches

Yes

Gear Grease

High Wear Protection

Motor

1/8th HP

Opening/Closing Force

Adjustable 5 to 30 lbs.

Arm Connection

1” Solid Spline Spindle

Adjustable Stop

Yes

Operator Switch

On-Off-Hold Open

Adjustable Spring Tension

Yes

Mechanical Clutch

Standard

Header Finish (Standard)

Clear, Dark Bronze, Extruded Aluminum

Header Finish (Optional)

Paint, Special Anodized Colors, Clad

Push or Pull Application

Yes

Easy Manual Operation

Yes

XP Spring

Optional

Surface Mounting

Yes

Concealed Mounting

Center Pivot, Hinge, or Offset Pivots

Bottom Loading

Optional

Push Reveal

0” to 14”

Pull Reveal

0” to 14”

Special Push & Pull Reveals

Call Us

Push & Go

Optional

Electric Strike Output Power

24 VDC

Fire Door Compatibility

UL10C Approved

Circuit Protection

3 A Fuse

Total Weight w/ 39” Header

45 lbs.

Meets ANSI 156.19

Yes

Additional Information
Option:Choose Lock Finish (Click here to see our Detailed Door Hardware Finish Guide):
https://blog.locksandsafes.com/2020/07/28/lock-and-door-hardware-finishes/
Option:Choose Hinge Finish (Click here to see our Detailed Door Hardware Finish Guide):
https://blog.locksandsafes.com/2020/07/28/lock-and-door-hardware-finishes/
Option:Choose Hinge Handing (What is it? Click link here to see our Door Handing Guide):
https://blog.locksandsafes.com/2020/07/28/door-hardware-handing-guide/
Icon Loading

Customer Reviews 0 Reviews Write a Review

This product hasn't received any reviews yet. Be the first to review this product!