Sargent 8271 Fail Secure Function Mortise Lock | Studio Lever on Rose | Sargent 8200 Grade 1 Electrified Mortise Locks
SARGENT 8200 Electromechanical Mortise locks are designed to handle single opening, stand alone applications, or can be readily integrated into sophisticated access control systems. They meet ANSI/BHMA A156.13 Grade 1 requirements, are UL listed on fire doors, and satisfy industry standards for operating temperature, shock and fire hazard.
FUNCTION
Fail Secure

INSIDE OUTSIDE
• Power ON, unlocks outside lever
• Specify voltage: 12VDC or 24VDC (operates from 12-24VDC)
• Key outside retracts latchbolt
• Lever outside retracts latchbolt, except when locked
• Lever outside can only be locked electronically
• Lever inside always retracts latchbolt
• Auxiliary deadlatch
SPECIFICATIONS
• For Doors 1-3⁄4" (44mm) thick standard
• Backset 2-3⁄4" (70mm) only
• Outside Front Plate Brass, bronze or stainless steel. 8" (203mm) x 1-1⁄4" (31mm), ANSI/BHMA Standard A156.115
• Front adjustable at any angle from flat to beveled 1⁄8" (3mm) in 2" (51mm)
• Hubs for Knobs/Levers – 7800: sintered iron copper infiltrated – 8200: cold forged steel
• Auxiliary Deadlatch is stainless steel and non-handed
• Specify hand on order; easily field reversible (if no hand is specified RH will be provided)
• Strike: Brass, bronze or stainless steel; ANSI Standard; curved lip, non-handed (strike box optional)
• Keys: Two, nickel silver (control key or emergency key must be ordered when required)
• Cylinder: Brass, size #41 (1-1/8") standard (except for Freewheeling, size #46 (1-3/4"))
• Can be masterkeyed or grand masterkeyed. Construction keying available. LA standard keyway
• Stile: 4-1/2" (114mm) minimum stile for 7800/8200, 4-3/4" (121mm) minimum stile for electrical function locks
• Door Prep: ANSI/BHMA A156.115 or A156.115W modified per template (see template)
MAXIMUM STRENGTH AND DURABILITY
• Sargent 8200 Series UL Cycle above and beyond test completed at 16 Million Cycles. Verification ID: V584148
• Certified to and exceeds ANSI/BHMA A156.13, Series 1000, Operational Grade 1 and Security Grade 1 with all standard trims
• Exceeds cycle testing requirements by 16 times the ANSI/BHMA A156.13 Grade 1 standard
• Case: 12 gauge heavy duty wrought steel, zinc dichromate plated. Thickness 7/64" (3mm) (.109")
• 1/8" (.125") cold-rolled steel inside front holds lock securely in door
• Heavy duty wrought steel hubs and high carbon steel spring cartridge provide superior strength and cycle life for 8200 locks
• Latchbolt is stainless steel with 3/4" (19mm) projection one-piece, anti-friction reversible latch
• Deadbolt is one-piece hardened stainless steel with 1" (25mm) projection
• Optional 8200 stainless steel hubs for Institutional setting (specify 3- option)
• Patent pending and/or patent www.assaabloydss.com/patents
MAXIMUM FLEXIBILITY
• Fast and easy installation. Lock is easily re-handed without removing parts or opening the lock case
• Aesthetic design. Many escutcheon and lever styles available to match a wide range of styles
• Many standard architectural grade finishes, including Polished Nickel (US14) & Satin Nickel (US15) finishes
• 54 functions including 4 electrical functions. The most in the industry for a broad range of applications
• Versatile. Offered for door thicknesses ranging from 1-3/8" (35mm) to 6" (152mm)
• Available with vandalism deterrent trim and/or secure fastener options Torx® and spanner screws for high abuse conditions
• Available with push/pull trim, perfect for hospital applications
• Status indicator options provide peace of mind on the locked/unlocked status of a door
Electrical Specifications
Voltage: Operates from 12-24VDC Regulated. Full wave rectification installed inside the lockbody.
Current:
• Actuator draw = .015 Amp continuous
• Maximum (2) locks per 1 Amp power supply (1/2 Amp peak current draw)
Operating Temp.: Max. 151°F (66°C), Min –31°F (-35°C)
UL and CUL listed for use on Fire Doors
Note: Repeated operation at voltage exceeding +/- 10% is not recommended
Warning
• Do not connect locks to a circuit sharing an additional electromagnetic device as the lock may be damaged
• Transient voltage must be suppressed at the source or before connecting with the lock
• Varistor rated at 35 volts (peak) may be used for transient voltage protection
Note: Opening the lockbody or the actuator replacement in the field by non-authorized personnel voids UL label and lock warranty