Command Access CAT-AIR-REX | Active Infrared Request to Exit Sensor
The CAT-AIR-REX improves accuracy of detection compared to the passive infrared by using focused active infrared to provide the most accurate detection of someone exiting a secured area. AIR-REX focuses right on the door handle solving the issues experienced with standard PIR’s: hot air, background objects, & cross traffic.
FEATURES
• Adjustable .5-60 Second Time Delay
• Adjustable Detection from 20-48”
• Adjustable Tilt Angle from 0-10 Degrees
• Built-In Sounder to Work in Conjunction with Door Position
• Multiple Re-Locking modes for Timed or Door Position Conditions
• 3 Dry Contact Inputs for REX, Card Reader, & Push Button
• Output Single Pole Double Throw
• LED Indicators
• UL294 Listed
• 3-Year “No Hassle” Warranty
SPECIFICATIONS
Detector Type
Focused Active Infrared
Supply Voltage
12 - 24 VAC / VDC; ± 10% @ 60 Hz
Current
Sounder OFF - 155mA
Sounder MAX VOLUME - 200 mA
Temperature (UL Install)
32 - 120 °F (0 - 49 °C)
Temperature
-20 - 120 °F (-29 - 49 °C)
Humidity
(ULC S319 Installation) - 0 - 93% non-condensing
(UL 294 Installation) - 0 - 85% non-condensing
Detection Range
20 - 48”, adjustable via potentiometer
Relay
2 Form “C” contact sets; 1.3 A @ 24 VAC / 30 VDC
Relay Hold Time
0.5 - 60 s, adjustable volume
Indicator LEDs
Green, Red, Yellow, Orange
REX Input
DRY contact, NO
Card Reader Input
DRY contact, NC
Door Position Switch Input
DRY contact, NO
Dimensions
6 7/10” (W) x 1 7/10” (D) x 2” (H)
Material
Plastic (ABS and PC)
Wiring Interface
JST (14-pin) with 4’ cable
Norm Conformity
UL 294 / ULC S319
FCC Part 15 B