Zoom the image with the mouse

Heavy Duty Electrically Unlocked (Fail Secure) Exit Lever Locks | Schlage ND12DEU

No reviews yet Write a Review
SKU:
SCH-ND12DEU
Shipping:
Calculated at Checkout
$646.49

Don't see the quantity, finish, or function you are looking for? We can mix, match and "BUILD" the item option set you are looking for - Just call us at 860-537-1328 and our sales staff will assist !

Selected Choose Lever is
Selected Choose Finish (Click here to see our Detailed Door Hardware Finish Guide) is
Adding to cart… The item has been added
  • Security Image 1
Description

View Latest Schlage Price ListView Schlage ND Series Installtion Guide

 

Looking for another ND series lock function? Click here to view all Schlage ND series lock functions

Schlage ND12DEU - Heavy Duty Electrically Unlocked (Fail Secure) Exit Lever Locks

The ND wired electrified lock complements the ND mechanical lock by working with access control systems to provide advanced security in high traffic areas. Because the electrified ND uses a motor instead of a solenoid, it offers unparalleled energy efficiency and flexibility in wired electrified applications.

More ECO. A maximum current draw of 0.23 amps not only saves energy, but by allowing more locks to run off a single power supply it saves money as well. The low 0.010 amp holding current eliminates any potential for hot levers in electrically locking applications or in electrically unlocking applications where the door is left open for long periods of time.

More FLEX. The electrified ND has flexibility for any application—it automatically operates from 12 to 24VDC, and the operating mode (electrically locked or unlocked) can be changed by simply toggling a switch on the chassis. Request to Exit (RX) can even be added with a simple upgrade kit.

The electrified ND has a number of other features and benefits. Incredibly quiet operation. Tested to over 4x BHMA standards. The electrified ND also comes standard with the Allegion connect Molex™ connector system (may be cut off and installed using traditional splicing methods if desired).

Function

Schlage ND12 EU - Keyless Electrified Exit

• Outside lever continuously unlocked (EU) by 12-24V DC.

• EU is fail secure (power fail locks outside lever).

• Inside lever always free for immediate egress.

Applications

Wired electrified locks complement the mechanical offering and are typically incorporated into a wired access control system or used independently with a remote access switch (e.g. switch behind a receptionist desk).

The electrified ND is ideally used in:

ƒ high traffic areas, where line power ensures continuous operation

ƒ new construction, where electrified door prep, hinges and wiring can easily be incorporated into the building

Key features

- Significantly exceeds ANSI/BHMA A156.2 requirements for Grade 1 cylindrical locks

- Nine lever designs, two rose designs

- 10 available finishes

- Supports standard, SFIC and FSIC cylinder formats

- Multiple key systems available – open, patented, restricted, geographic exclusive, UL437

- auto-detecting 12-24VDC input

- selectable EL/EU operation

- low 0.23 amp max current draw that allows multiple locks on a single power supply

- low 0.010 amp holding current that eliminates “hot levers” in electrically locked applications

- modular Request to Exit (RX) that can be added at any time

- inventory friendly–one lock supports 12-24V, EL or EU, with or without RX

- six electrified functions for application flexibility

ND mechanical specifications

Chassis

1. Material: Modular design of zinc and steel components plated for corrosion protection

2. Door thickness: Standard: 1 5⁄8" to 2 1 ⁄8" Optional: 1 3⁄8" - 6" EE, EO, EI, ED configurations

Trim

1. Handing: Non-Handed

2. Levers: Standard: Nine designs, pressure cast zinc, plated to match product finish specification Optional: Tactile feature - Athens (ATH), Rhodes (RHO), Sparta (SPA), Tubular (TLR), LAT (Latitude), LON (Longitude), BRW (Broadway), BRK (Boardwalk)

3. Roses: Wrought brass, bronze, or zinc, plated to match product finish specification

4. Finishes: 10 available (605, 606, 612, 613, 619, 622, 625, 626, 626AM, 643e)

Latches

1. Backset: Standard: 2 3⁄4" Optional: 2 3⁄8", 3 3⁄4", 7 3⁄4"

2. Faceplate: Standard : 1 1 ⁄8" x 2 1 ⁄4" Optional: 1" x 2 1 ⁄4" for 2 3⁄8" backset doors

3. Bolt: Standard : 1 ⁄2" throw via Oil Impregnated Stainless Steel Optional : 3⁄4" throw anti-friction bolt available for pairs of doors

4. Strike: Standard: ANSI Curved Lip: 1 1 ⁄4" x 4 7 ⁄8" x 1 3⁄16" Optional: T Strike, ANSI strikes with alternative lip lengths, dust box options

Wired electrified | Schlage ND-12EU Electrically Unlocked Exit Lock

1. Input voltage: Autodetecting 12-24V DC, + 10%

2. Operating mode: Fail Safe or Fail Secure via switch on chassis

3. Current draw: 0.23 amps maximum; 0.01 amps holding

4. Request to Exit: Modular - 3A @ 125VAC / 2A @ 30VDC

Warranty

Mechanical: 1 year wired electrified

Certifications

1. ANSI/BHMA: Wired electrified complies with A156.25 (indoor)

2. ICC: Complies with ICC A117.1 Accessible and Usable Buildings and Facilities

3. UL/cUL: All locks 3 hour A label single firedoor 4'0" x 10'0"; pair doors 3 hour firedoor 8'0" x 8'0" with 3⁄4" latch option; pair doors 90 minute fire 8'0" x 10'0" with 3⁄4" latch option

4. CA Fire Code: All levers with a return to door of 1 ⁄2" (64 mm) or less comply (Rhodes, Sparta, Tubular, Omega, Longitude and Boardwalk)

5. FL Building Code: Complies with Florida Building Code (ASTM E330, E1886, E1996) and Miami Dade (TAS 201, 202, 203) requirements for hurricanes

6. Federal: Meets FF-H-106C Series 161

Electrical requirements

ƒ Input voltage: auto-detects 10.8-26.8VDC

ƒ Max current draw: 0.230 amp (230mA)

ƒ Holding current: 0.010 amp (10mA)

ƒ Temperature range: 32°F-120°F (0°-49°C)

Request to Exit (RX)

ƒ Normally open, normally closed and common leads provided

ƒ Electrical rating: 2A, 30VDC max

ƒ Order (with lock): specify RX in option field

ƒ Order (retrofit): p/n N123-062

Schlage ND12EU comes with an optional Tactile warning for the visually impaired

Tactile warning is a special texture applied to the outside lever to alert the visually impaired to a potential hazard on the opposite side of the door (exit to street, a workshop or other hazardous area, etc). Tactile warning is typically applied to the outside lever only, and is specified by an 8 prefix on the lever design

SchlageND12EU Series Tactile Warning for Visually Impaired

Strikes available for the Schlage ND12EU Cylindrical Lock

Available Strikes for Schlage ND-12EU Series Locks

Wiring Instruction for Schlage ND 12 EU Fail Secure Exit Lock

Schlage ND12EU Wired Electric Cylindrical Lock Wiring Instruction

Detailed Look

Schlage ND 12 EU Wired Electric Cylindrical Lock Detailed Look

Looking for Another ND Series Lock Function?

Non Keyed

ANSI No.FunctionFunction DescriptionLink to Lock
F75 ND10S - Passage Latch • Both levers always unlocked. Click here to view Schlage ND10S
F89 ND12D - Exit Lock • Outside lever always fixed.
• Inside lever always free for immediate egress.
Click here to view Schlage ND12D
- ND25D - Exit Lock with Blank Plate Outside • Blank plate outside.
• Inside lever always free for immediate egress.
Click here to view Schlage ND25D
F77 ND30D - Patio Lock • Push button locking.
• Turning inside lever or closing door releases button, preventing a lock-out.
•Inside lever always unlocked for immediate egress.
Click here to view Schlage ND30D
F76 ND40S - Bath/Bedroom Privacy Lock • Push-button locking.
• Unlocked from outside with a small screwdriver.
• Turn inside lever or close door to release button.
• Inside lever always free for immediate egress.
Click here to view Schlage ND40S
- ND44S - Hospital Privacy Lock • Push-button locking.
• Unlocked from outside by turning emergency turnbutton.
• Turn inside lever or close door to release button.
• Inside lever always free for immediate egress.
Click here to view Schlage ND44S
- ND45 - Timeout Lock • Caretaker side: Pushing and holding button will lock inside lever (detention side) until released. Lever always retracts latch.
• Detention side: Lever retracts latch unless outside button is depressed. Vandlgard allows inside spindle to disengage from latch when locked
Click here to view Schlage ND45
- ND170 - Single Dummy Trim • Dummy trim for one side of door.
• Used for door pull or as matching inactive trim.
Click here to view Schlage ND170
- ND172 - Double Dummy Trim • Dual dummy trim for both sides of the door.
• Used for door pull or as matching inactive trim
Click here to view Schlage ND172

Keyed

ANSI No.FunctionFunction DescriptionLink to Lock
F82 ND50PD - Entrance/Office Lock • Push-button locking.
• Push-button locks outside lever until it is unlocked with key or by turning inside lever.
• Inside lever always free for immediate egress.
Click here to view Schlage ND50PD
F109 ND53PD - Entrance Lock • Turn/push-button locking: Pushing and turning the button locks the outside lever, requiring use of a key until the button is manually unlocked.
• Push-button locking: Pushing button locks outside lever until unlocked by key or by turning the inside lever.
• Inside lever always free for immediate egress
Click here to view Schlage ND53PD
F88 ND60PD - Vestibule Lock • Latch retracted by key from outside when outside lever is locked by key in inside lever.
• Inside lever always free for immediate egress.
Click here to view Schlage ND60PD
- ND60PD - Vestibule with Closed Lever • Same as ND60 except outside lever is closed. Inside lever always unlocked for immediate egress. Click here to view Schlage ND60PD
F91 ND66PD - Store Lock • Key in either lever locks or unlocks both levers. Click here to view Schlage ND66PD
F84 ND70PD - Store Lock • Outside lever locked and unlocked by key.
• Inside lever always free for immediate egress.
Click here to view Schlage ND70PD
F80 ND72PD - Communicating Lock • Key in either lever locks and unlocks own lever. Click here to view Schlage ND72PD
F90 ND73PD - Corridor Lock • Locked or unlocked by key from outside.
• Push-button locking from inside.
• Turn inside lever or close door to release button.
• When outside lever is locked by key it can only be unlocked by key.
• Inside lever always free for immediate egress.
Click here to view Schlage ND73PD
- ND75PD - Classroom Security Lock • Key in either lever locks or unlocks outside lever.
• Inside lever always free for immediate egress.
Click here to view Schlage ND75PD
F86 ND80PD - Storeroom Lock • Outside lever is fixed.
• Entrance by key only.
• Inside lever always free for immediate egress
Click here to view Schlage ND80PD
F87 ND82PD - Institution Lock • Both levers always fixed.
• Entrance by key in either lever
Click here to view Schlage ND82PD
- ND85PD - Faculty Restroom Lock • Outside lever is fixed. • Entrance by key only.
• Visual occupancy indicator, allowing only emergency key to operate.
• Turn inside lever or close door to unlock.
• Rotation of inside spinnerbutton enables lock-out feature.
• Inside lever always free for immediate egress.
• Not available with interchangable core cylinders.
Click here to view Schlage ND85PD
- ND25x70PD - Classroom Exit Lock • Blank plate outside.
• Key locks or unlocks inside lever.
Click here to view Schlage ND25x70PD
- ND25x80PD - Storeroom Exit Lock • Blank plate outside.
• Key in fixed inside lever retracts latch.
Click here to view Schlage ND25x80PD
- ND70x80PD - Classroom By Storeroom Lock • Key locks and unlocks outside lever.
• Key in fixed inside lever retracts latch.
Click here to view Schlage ND70x80PD

Locks with Vandlgard Levers

ANSI No.FunctionFunction DescriptionLink to Lock
- ND72PD - Communicating Lock • Key in either lever locks and unlocks own lever.
• Both inside and outside levers are clutching.
Click here to view Schlage ND72PD
F82 ND91PD - Entrance/Office Lock • Push-button locking.
• Push-button disengages outside lever until unlocked with key or by turning inside lever.
• Vandlgard allows outside spindle to disengage from latch when locked.
• Inside lever always free for immediate egress.
Click here to view Schlage ND91PD
F109 ND92PD - Entrance Lock • Turn/push-button locking: Pushing and turning button disengages outside lever, requiring using of key until button is manually unlocked.
• Push-button locking: Pushing button disengages outside lever until unlocked by key or by turning inside lever.
• Vandlgard allows outside spindle to disengage from latch when locked.
• Inside lever always free for immediate egress.
Click here to view Schlage ND92PD
F88 ND93PD - Vestibule Lock • Latch retracted by key from outside when outside lever is disengaged by key in inside lever.
• Vandlgard allows outside spindle to disengage from latch when locked.
• Inside lever always free for immediate egress.
Click here to view Schlage ND93PD
F84 ND94PD - Classroom Lock • Outside lever disengaged and unlocked by key.
• Vandlgard allows outside spindle to disengage from latch when locked.
• Inside lever always free for immediate egress.
Click here to view Schlage ND94PD
- ND95PD - Classroom Security Lock • Key in either lever locks or unlocks outside lever.
• Vandlgard allows outside spindle to disengage from latch when locked.
• Inside lever always free for immediate egress.
Click here to view Schlage ND95PD
F86 ND96PD - Storeroom Lock • Outside lever always disengaged.
• Entrance by key only.
• Vandlgard allows outside spindle to disengage from latch when locked.
• Inside lever always free for immediate egress.
Click here to view Schlage ND96PD
F90 ND97PD - Corridor Lock • Locked or unlocked by key from outside.
• Push-button locking from inside.
• Turning inside lever or closing door releases button.
• When outside lever is locked by key it can only be unlocked by key.
• Vandlgard allows outside spindle to disengage from latch when locked.
• Inside lever always free for immediate egress
Click here to view Schlage ND97PD

Wired Electrified Locks

ANSI No.FunctionFunction DescriptionLink to Lock
- ND12EL - Keyless Electrified Exit • Outside lever continuously locked (EL) by 12-24V DC.
• EL is fail safe (power fail unlocks outside lever).
• Inside lever always free for immediate egress.
Click here to view Schlage ND12EL
- ND12EU - Keyless Electrified Exit • Outside lever continuously unlocked (EU) by 12-24V DC.
• EU is fail secure (power fail locks outside lever).
• Inside lever always free for immediate egress.
Click here to view Schlage ND12EU
- ND80EL - Electrified Storeroom • Outside lever continuously locked (EL) by 12-24V DC.
• EL is fail safe (power fail unlocks outside lever).
• Key outside serves as mechanical override.
• Inside lever always free for immediate egress.
Click here to view Schlage ND80EL
- ND80EU - Electrified Storeroom • Outside lever continuously unlocked (EU) by 12-24V DC.
• EU is fail secure (power fail locks outside lever).
• Key outside serves as mechanical override.
• Inside lever always free for immediate egress.
Click here to view Schlage ND80EU
- ND96EL - Electrified Storeroom with Vandlgard • Adds Vandlgard to ND80EL/EU.
• Vandlgard allows outside spindle to disengage from latch when locked, limiting the ability of vandals to apply excessive force to the chassis. See page 16 for more details.
Click here to view Schlage ND96EL
- ND96EU - Electrified Storeroom with Vandlgard • Adds Vandlgard to ND80EL/EU.
• Vandlgard allows outside spindle to disengage from latch when locked, limiting the ability of vandals to apply excessive force to the chassis. See page 16 for more details.
Click here to view Schlage ND96EU
Additional Information
Option:Choose Finish (Click here to see our Detailed Door Hardware Finish Guide):
https://blog.locksandsafes.com/2020/07/28/lock-and-door-hardware-finishes/
Option:Choose Backset (What is a Backset? Click here to read our blog explaining Backset):
https://blog.locksandsafes.com/2021/02/02/what-is-a-backset/
Icon Loading

Customer Reviews 0 Reviews Write a Review

This product hasn't received any reviews yet. Be the first to review this product!