Corbin Russwin ED2400 | ED2000 Series Vertical Rod Exit Device
Corbin Russwin ED2000 Series - Applications and Listings

Features
Handing
Handed, specify hand (field reversible)
Bar Length
Easily field cut to size.
Standard: 36" (914mm) bar fits 30"- 36" (762mm-914mm) door.
Optional: 24" (610mm) bar fits 24" (610mm) door; specify W024.
Optional: 48" (1219mm) bar fits 36"-48" (914mm-1219mm) door; specify W048.
Latchbolt
Top: 3/4" (19mm) throw, stainless steel pullman-type with automatic deadlatching.
Bottom: 5/8" (16mm) throw deadbolt, held retracted during door swing.
Door Opening Length
-36 for 30" - 36" (76cm - 91cm) doors
-42 for 36" - 42" (91cm - 107cm) doors
-48 for 42" - 48" (107cm - 122cm) doors
Door Opening Height
Standard door height 7' (213cm), with the device centerline at 39-15/16" (101cm) from floor Optional heights up to 8' (244cm) by using rod extensions
Door Thickness
1-3/4" (44mm) standard.
Minimum Stile Width
4-1/2" (114mm)
Projection
Minimum width 5" (127mm).
Projection
2-1/2" (64mm) active, 1-3/4" (44mm) depressed
Strike
Top: adjustable strike with positive locking plate and shims.
Bottom: flush mounted.
Certification/Compliance
ANSI/BHMA Certified
A156.3 Type 1, Grade 1
UL/cUL Listed
FVSR/FVSR7 - Panic hardware
GXHX/GXHX7 - Fire exit hardware (F) (up to 4' x 8' single, 8' x 8' pairs, 3 hr.)
All devices listed for safety as panic hardware; devices comply with UL 305 standards for panic hardware. UL symbol on rear cover label indicates listing Three hour fire-rated devices listed as fire exit hardware for A label and lesser class 4' x 8' single or 8' x 8' double doors; UL symbol on rear cover label indicates listing. Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and Corbin Russwin, Inc. makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings.
California State Reference Code
This product has been approved by the California State Fire Marshal pursuant to section 13144.1 of the California Health and Safety Code.
NFPA
All exit devices comply with NFPA 101 Life Safety Code. All fire-rated devices comply with NFPA 80 Fire Doors and Windows.
ADA
Exit devices, lever trims and pulls comply with Americans with Disabilities Act.