Falcon MEL-F-25-C-EO | Grade 1 Fire Rated Concealed Vertical Rod Exit Device with Motorized Electric Latch Retraction
The Falcon MEL-F-25-C-EO is a Grade 1 concealed vertical rod exit device featuring Motorized Electric Latch Retraction. The Motorized Electric Latch Retraction feature adds electronic access control to your exit device. So now you can replace manual dogging with motorized electric latch retraction on your Falcon MEL-F25C exit device. This adds convenience, because you can now remotely retract the latchbolt.
Motorized electric latch retraction on your Falcon MEL-F-25-C fire cvr exit device can be used with credential readers to unlatch doors momentarily for authorized users. Motorized electric latch retraction on your Falcon MEL-F-25C exit device can also be incorporated with systems to retract latches for extended periods of time to allow free entry.
Since the Falcon MEL-F25-C is a fire exit hardware, it must be self latching. So in order to use motorized electric latch retraction, an automatic fire alarm system must be incorporated to drop power to fire rated MEL devices in case of fire.
Specifications of Falcon MEL-F-25-C Fire Rated Concealed Vertical Rod Exit Device with Motorized Electric Latch Retraction
Hand
Field reversible
UL
“A” label (3 hr.); 4'0" x 10'0" single doors; 8'0" x 10'0" pair of doors (F-25-M x F-25-V or F-25-C).
Finishes
US3 (605); US4 (606); US10 (612); US11 (643e); US15 (619); US19 (622); US26 (625); US26D (626); US32 (629); US32D (630); US28 (628), 313AN (710).
See our guide on door hardware finishes here.
Strikes
4188 mortised top, 2130 bottom standard
Latchbolt
Stainless steel, 3⁄4" throw.
Deadlocking latchbolt
Standard
Stock sizes
See chart
Doors
1 3⁄4" thick, wood or metal. Specify thickness if other than 1 3⁄4".
Projection
2 3⁄4" maximum
Stile
4" minimum
Mounting height
40 1 ⁄4" from CL to finished floor
Electric functions
Can be interfaced with building security systems. Motorized electric latch retraction (fail secure only), FSA/FSE trim, security monitoring, delayed egress and exit alarm available.
Fasteners
All mounting screws are concealed. All machine screws (AMS) standard.
Sex bolts
Required when used with wood, composite or non-reinforced hollow metal doors. For EO device specify 6 - 425 (#10-24) SNB. For devices with trim, specify 2 - 425 (#10-24) SNB.
ANSI
Certified ANSI A156.3-2001 grade 1 standards.
25-C-LBR
Less bottom rod, auxiliary fire pin required per pair
Vertical rods
Furnished to length based on 40 1 ⁄4" horizontal CL to finished floor and a 7'0" door. Variations from these standards must be specified when ordering.
Shim kits
Consult factory
Door Application
1. Device: 25-C
Door size: 3'
Door strike: All
Min stile (in): l 4" (6 1 ⁄2" for wood doors)
Min door opening width: 2' 7 1 ⁄8"
2. Device: 25-C
Door size: 4'
Door strike: All
Min stile (in): l 4" (6 1 ⁄2" for wood doors)
Min door opening width: 3' 1 1 ⁄8"
Motorized Electric Latch Retraction Specification
MEL electrical load
Voltage: 24 VDC
Current: 1.0 A Inrush (0.5 sec) 0.14 A Holding
- Option:Choose Finish (Click here to see our Detailed Door Hardware Finish Guide):
- https://blog.locksandsafes.com/2020/07/28/lock-and-door-hardware-finishes/
- Option:Choose Handing (What is it? Click link here to see our Door Handing Guide):
- https://blog.locksandsafes.com/2020/07/28/door-hardware-handing-guide/